Products

I/O Expansion

1065 16-input/4-output

The 1065 is used to increase the number of alarm input/output points of any Pacom Controller; providing 16 supervised alarm inputs and four outputs. It communicates with the Controller over an RS485 multi-drop device loop.

The input/output capacity of the 1065 can also be increased by installing up to two Pacom 1050-003 (8-output Controller expansion card)/1050-004 (16-input Controller expansion card). These cards can be installed in any combination to increase the 1065 input/output capacity to either:

  • 48 inputs and four outputs.
  • 32 inputs and 12 outputs.
  • 16 inputs and 20 outputs, depending on configuration.

1050-003 8-output

The 1050R-003 is used to increase the number of alarm output points of Pacom 105x Controllers; providing eight relay controlled outputs. The module can also be added to the 1065.

1050-004 16-input

The 1050R-004 is used to increase the number of alarm input points of Pacom 105x Controllers; providing 16 supervised alarm inputs. The module can also be added to the 1065.

1076-IO 8-input/4-output

The 1076R-IO is used to increase the number of alarm input/output points of any Pacom Controller; providing eight supervised alarm inputs and four relay controlled outputs. It communicates with the Controller over an RS485 multi-drop device loop.

1068 2-input/1-output

The 1068 is designed to increase the security of remote alarm input devices such as PIRs, door contacts or seismic detectors. It is small enough to be housed inside the casing of most devices, comes with a universal mounting bracket, and has two inputs to allow monitoring of the device contact and an additional tamper switch.

The 1068 replaces the standard resistance monitored line to the Pacom Controller with an RS485 data link that can be encrypted, if required. It is constantly polled by the Controller and, if a valid response to the poll is not received, the Controller reports an alarm. By connecting sensor devices to the security system in this way, the possibility of a device being tampered with or substituted without detection is virtually eliminated.

The inputs support analog data (0 to 5VDC) and can be used to facilitate remote maintenance from GMS. It is equipped with an output relay that can be used to activate an LED and a buzzer for a seismic detector self-testing or a range of other purposes.

The 1068 can also be used as an interface for programming Inovonics devices.